Smarter COD Hardware Performance Analyst: Chemical Oxygen Demand
For more parameters, please contact the company's sales department and also refer to the incomplete parameter list
|
■ |
Analysis range |
0-5mg/L (customizable) |
|
|
■ |
detection limit |
1mg/L |
|
|
■ |
resolution ratio |
0.1mg/L |
|
|
■ |
error |
±3% |
|
|
■ |
repetitiveness |
±5% |
|
|
■ |
Range drift |
±5% |
|
|
■ |
Decomposition temperature |
120℃ (adjustable) |
|
|
■ |
Reduce the duration of digestion |
30min (settable) |
|
|
■ |
analysis mode |
integral point |
Run by the hour, up to 24 groups per day |
|
margin |
Run at set intervals |
||
|
hand movement |
Manual analysis |
||
|
long-range |
Remote control by MODBUS; dry contact control |
||
|
■ |
Calibration method |
Number of intervals |
The interval was calibrated according to the cumulative analysis |
|
Number of days between intervals |
Interval calibration is performed according to the number of running days |
||
|
hand movement |
Manual calibration |
||
|
long-range |
Remote control is performed in MODBUS mode |
||
|
■ |
Cleaning method |
voluntarily |
Analysis cleaning; fault cleaning; abnormal power failure cleaning; emergency shutdown cleaning |
|
hand movement |
Clean by hand |
||
|
■ |
report to the police |
Low level alarm; self-test alarm; fault alarm; out of specification alarm (one relay) |
|
|
■ |
data |
The 4-20mA analog signal is available throughout the journey |
|
|
■ |
communication |
An RS232 or RS485 interface standard MODBUS protocol |
|
|
■ |
memory |
About 20,000 groups (power off automatic save); support USB drive export EXCEL; |
|
|
■ |
put a seal on |
Micro industrial thermal printer (optional) |
|
|
■ |
Reagent quantity |
About 180 times per set |
|
|
■ |
Maintenance cycle |
About 30 days, 45 minutes |
|
|
■ |
cell display |
7 inch LCD, 800*480 resolution, TFT true color touch screen |
|
|
■ |
service environment |
5-35℃, humidity <90% (no condensation) |
|
|
■ |
Water sample temperature |
5—35℃ |
|
|
■ |
Water harvesting unit |
Used for water sample circulation and retention; automatic backwash precision filtration system (optional) |
|
|
■ |
size |
73cm×47cm×28cm |
|
|
■ |
weight |
25KG |
|
|
■ |
source |
AC 220V ± 10%, 50Hz ± 1% |
|
|
■ |
power |
150W |
|
*There are three different levels of operation: basic level, advanced level, and protection level, all of which can set usernames and
passwords to protect experimental data;
Absolute bidirectional data transmission between PC and analyzer;
Automatically retrieve installed hardware;
Confirmation function: Display when power is off;
Dynamic curve function with up to 3 calibration points;
Having the function of historical data curve;
Can be exported to an Excel file;
The instrument's built-in memory can store at least 100000 sets of data;
Can be remotely operated (Lumineux only)